import serial
|
||
|
import logging
|
||
|
|
||
|
import modbus_tk
|
||
|
import modbus_tk.defines as cst
|
||
|
from modbus_tk import modbus_rtu
|
||
|
|
||
|
class inst_temp:
|
||
|
def __init__(self,com,band):
|
||
|
#self.logger = modbus_tk.utils.create_logger("dummy")
|
||
|
self.logger = logging.getLogger("modbus_tk")
|
||
|
if not self.logger.handlers:
|
||
|
self.logger = modbus_tk.utils.create_logger("console")
|
||
|
#self.ser = serial.Serial(com,band,bytesize=8, parity='N', stopbits=1)
|
||
|
try:
|
||
|
self.master = modbus_rtu.RtuMaster(
|
||
|
serial.Serial(com, band, bytesize=8, parity='N', stopbits=1)
|
||
|
)
|
||
|
self.master.set_timeout(5.0)
|
||
|
self.master.set_verbose(True)
|
||
|
self.logger.info("connected")
|
||
|
print("*-----------------------------*")
|
||
|
print("* TEMP Connected. *")
|
||
|
except modbus_tk.modbus.ModbusError as exc:
|
||
|
self.logger.error("%s- Code=%d", exc, exc.get_exception_code())
|
||
|
|
||
|
def temp_on(self):
|
||
|
try:
|
||
|
self.logger.info(self.master.execute(1, cst.WRITE_SINGLE_COIL, 212, output_value=256))
|
||
|
self.logger.info(self.master.execute(1, cst.WRITE_SINGLE_COIL, 1200, output_value=256))
|
||
|
except modbus_tk.modbus.ModbusError as exc:
|
||
|
self.logger.error("%s- Code=%d", exc, exc.get_exception_code())
|
||
|
print("temp on")
|
||
|
|
||
|
def temp_off(self):
|
||
|
try:
|
||
|
self.logger.info(self.master.execute(1, cst.WRITE_SINGLE_COIL, 212, output_value=256))
|
||
|
self.logger.info(self.master.execute(1, cst.WRITE_SINGLE_COIL, 1200, output_value=0))
|
||
|
except modbus_tk.modbus.ModbusError as exc:
|
||
|
self.logger.error("%s- Code=%d", exc, exc.get_exception_code())
|
||
|
print("temp off")
|
||
|
|
||
|
def read_temp(self):
|
||
|
print("read temp")
|
||
|
|
||
|
def write_temp(self,temp):
|
||
|
print("write temp")
|
||
|
|
||
|
def temp_close(self):
|
||
|
self.master.close()
|
||
|
print("* TEMP unConnected. *")
|
||
|
print("*-----------------------------*")
|